humiDisk ¿ø½É½Ä °¡½À±â´Â ¸ðÅÍÀÇ °í¼Ó ȸÀü ½Ã µð½ºÅ©ÀÇ ¿ø½É·ÂÀ» ÀÌ¿ëÇÏ¿© ¹°À» ºñ»ê½ÃŰ°í ³»ºÎ ÆÇ¿¡ Ãæµ¹½ÃÄÑ ¹°À» °ø±â Áß¿¡ ¹Ì¼¼ ºÐ¹«ÇÏ´Â ¹æ½ÄÀÔ´Ï´Ù

 

HumiDisk Á¦Ç° Ư¡

- 6.5kg/h ³ôÀº ºÐ¹«·®
- °íÀåÀÌ ¾ø°í ³»±¸¼ºÀÌ ¾ÆÁÖ ÁÁÀ½
- Water tank ³» ÀÚµ¿ ¹è¼ö ½Ã½ºÅÛ ±â´É
- Air Filter ³»ÀåÀ¸·Î ¿À¿° ÃÖ¼ÒÈ­
- ¾ÆÁÖ ÀÛÀº ¿¡³ÊÁö ¼Òºñ 30W/ kg/h
- ½Àµµ ¼¾¼­¿¡ ÀÇÇÑ ÀÚµ¿ on/off
- ºÐ¹«·® Á¶Àý °¡´É
- Àú¿ÂÀúÀå°í, ¿Â½Ç, ÀÛÀº â°í µî¿¡ À¯¸®

 

HumiDisk ¼³Ä¡ »ç·Ê

 

HumiDisk Á¦Ç° »ç¾ç

Model

humiDisk65

humiDisk10

Capacity

6.5 kg/h, adjustable from 0.85 to 6.5 kg/h (1.9 to 14.3 lb/h)

1 kg/h (2.2 lb/h) at 230 V 50 Hz1.2 kg/h (2.6 lb/h) at 110 V 60 Hz

Power supply

230 V, 50 Hz - 110 V, 60 Hz

230 V, 50 Hz - 110 V, 60 Hz

Power input

230 W - (290 W with antifreeze device)

31 W

Air flow-rate

280 m³/hour (165 CFM)

80 m³/hour (47 CFM)

Water content

0.055 litres (0.12lb)

0.055 litres (0.12lb)

Operating conditions

1T35 °C (+34 to +95°F) WITHOUT antifreeze device

1T35 °C (+34 to +95°F)

-2T35 °C WITH antifreeze device (not available for the American version)

-

0 to 100% RH non-condensing

0 to 100% RH non-condensing

Antifreeze heater

yes (European version only)

no

Electronic board for capacity control

yes

no

Electrical panel with electronic humidistat

yes (optional)

no

Mechanical humidistat

yes (optional)

yes (optional)

Installation accessories

accessories for ceiling and wall-hung installation, supply and drain hoses included.

accessories for ceiling installation INCLUDED.
Accessories for wall-hung installation and hoses.
NOT INCLUDED, available as optionals.

Index of protection

IPX4

IPX4

Supply water pressure

100 to 1000 kPa

100 to 1000 kPa

Water temperature limits

+1 °C (+33.8 °F) to +50 °C (+122 °F)

+1 °C (+33.8 °F) to +50 °C (+122 °F)

Limits in the total hardness of the water (*)(**)

max 30 °FH (max 300 ppm CaCO3)

max 30 °FH (max 300 ppm CaCO3)

Limits water conductivity (**)

100 to 1200 ¥ìS/cm

100 to 1200 ¥ìS/cm

Certifi cation

CE and ETL

CE and ETL

 

(*) not less than 200% of Cl- in mg/l
(**) The quantity and the quality of the minerals dissolved in the water aff ect the frequency of the routine maintenance operations and the amount of dust generated.
For best operation, use demineralised water (not softened, as this does not reduce the content of minerals dissolved in the water). At any rate, it is suggested to follow the specifi cations of the UNI 8884 standard, ¡°Characteristics and treatment of the water in cooling and humidifi cation circuits¡±, conductivity <100 ¥ìS/cm; total hardness<5 °fH (50 ppm CaCO3).